Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Braz. dent. sci ; 27(1): 1-11, 2024. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1537767

RESUMO

Objective: This systematic review aims to compare the clinical longevity of metallic and fiberglass intraradicular posts in teeth with severely compromised crowns, utilizing randomized clinical trials and case reports published in the last eleven years. Material and Methods: The research was conducted on PubMed, Medline, Lilacs, and BBO databases using the first search strategy with the descriptors 'dental posts,' 'longevity,' 'fiberglass-reinforced posts' or 'metallic posts.' The second search strategy involved analyzing the references of articles identified by the first search. Both studies were carried out with stringent inclusion and exclusion criteria. Results: No statistically significant and clinically relevant differences in longevity were observed between metallic and fiberglass posts. Conclusion: The clinical success and durability of the restorative procedure using intraradicular posts primarily depend on the remaining amount around the post (ferrule), the type and position of the tooth in the arch (impacting the masticatory forces exerted on the restored tooth), and the correct application of the cementation technique. It is noteworthy that fiberglass posts offer substantial advantages by presenting a modulus of elasticity similar to dental structure, ensuring a more homogeneous distribution of masticatory forces and reducing the risk of fractures. These findings have practical implications for material selection in restorative procedures involving intraradicular posts.(AU)


Objetivo: Esta revisão sistemática visa comparar a longevidade clínica de pinos intrarradiculares metálicos e de fibra de vidro em dentes com coroas severamente comprometidas, através de estudos clínicos randomizados e relatos de casos, publicados nos últimos onze anos. Material e Métodos: A pesquisa foi conduzida nas bases de dados PubMed, Medline, Lilacs e BBO, utilizando a primeira estratégia de busca com os s 'pinos dentais' e 'longevidade' e 'pinos reforçados com fibra de vidro' ou 'pinos metálicos'. A segunda estratégia de busca consistiu na análise das referências dos artigos identificados pela primeira estratégia. Ambos os estudos foram delineados com critérios rigorosos de inclusão e exclusão. Resultados: Não se constataram diferenças estatisticamente significativas e clinicamente relevantes na longevidade entre pinos metálicos e de fibra de vidro. Conclusão: O êxito clínico e a durabilidade do procedimento restaurador empregando pinos intrarradiculares dependem primordialmente da quantidade de remanescente ao redor do pino (férula), do tipo e posição do dente na arcada (o que impacta nas forças mastigatórias exercidas sobre o dente restaurado) e da aplicação correta da técnica de cimentação.Destaca-se que o pino de fibra de vidro oferece vantagens substanciais ao apresentar módulo de elasticidade similar à estrutura dentária, assegurando uma distribuição mais homogênea das forças mastigatórias e reduzindo o risco de fraturas (AU)


Assuntos
Materiais Dentários , Pinos Dentários
2.
São José dos Campos; s.n; 2023. 47 p. ilus, tab.
Tese em Português | BBO - Odontologia | ID: biblio-1425173

RESUMO

O objetivo deste trabalho foi avaliar, ex vivo, pelo teste de compressão e ciclagem, a resistência a fratura de dentes que tiveram suas raízes fragilizadas em laboratório que receberam reforço intrarradicular com um modelo de pino de fibra de vidro Splendor-SAP em comparação ao pino de fibra de vidro Exacto. Além disso, foi realizada análise por elementos finitos para identificar os pontos de maior estresse estrutural. Foram utilizadas 60 raízes de dentes bovinos, os espécimes foram seccionados e padronizados com 16 mm de comprimento. Os canais foram instrumentados em toda a sua extensão utilizando limas endodônticas manuais. As amostras foram aleatoriamente distribuídas em seis grupos acordo com a espessura do remanescente radicular medidos a partir do terço cervical (2 mm e 3 mm) e o reforço radicular a ser utilizado (n=10): G1 - Controle 1, com remanescente radicular de 2 mm e sem reforço intrarradicular; G2 - Controle 2, com remanescente radicular de 3 mm e sem reforço intrarradicular; G3 - Com remanescente de 2 mm e reforço intrarradicular utilizando pino Exacto; G4 - Com remanescente radicular de 3 mm e reforço intrarradicular utilizando Exacto; G5 - Com remanescente radicular de 2 mm e reforço intrarradicular utilizando Splendor-SAP; G6 - Com remanescente radicular de 3 mm e reforço intrarradicular utilizando Splendor-SAP. Para a fragilização simulada, o desgaste radicular foi de 12 mm no interior do canal. Em seguida, os canais foram obturados e o material obturador removido dos terços cervical e médio, restando apenas 4 mm de material no terço apical. A cimentação dos pinos foi realizada seguindo o protocolo do fabricante. O teste de fadiga foi realizado por ciclagem mecânica dos espécimes para o envelhecimento das mesmas (1200000 ciclos; 3.8 Hz; carga = 88 N). Foi realizado o teste de compressão pela máquina de Ensaios Universais, com célula de carga de 100 Kg à velocidade de 1 mm/min com incidência a 45°. Os valores médios de resistência à fratura encontrados para os grupos, em ordem crescente, foram: G1 - 9,045 kgf, G2 - 9,753 kgf, G3 - 68,411 kgf, G4 - 80,167 kgf, G5 - 70,551 e G6 - 80,027. Os espécimes foram analisados em estereomicroscópio para classificação do modo de falha. Os resultados obtidos foram submetidos à análise estatística (ANOVA e Tukey) que demonstrou diferença estatisticamente significativa (p<0,05) (AU)


The objective of this work was to evaluate, ex vivo, by compression and cycling test, the resistance to fracture of teeth that had their roots weakened in the laboratory and that received intraradicular reinforcement with a Splendor-SAP fiberglass post model in comparison to the Exact fiberglass pin. In addition, finite element analysis was performed to identify the points of greatest structural stress. Sixty roots of bovine teeth were used, the specimens were sectioned and standardized with 16mm in length. The canals were instrumented along their entire length using manual endodontic files. The samples were randomly distributed into six groups according to the thickness of the root remnant (2 mm and 3 mm) and the root reinforcement to be used (n=10): G1 - Control 1, with a 2 mm root remnant and without intraradicular reinforcement ; G2 - Control 2, with root remnant of 3 mm and without intraradicular reinforcement; G3 - With a 2 mm remnant and intraradicular reinforcement using an Exacto post; G4 - With root remnant of 3 mm and intraradicular reinforcement using Exacto; G5 - With root remnant of 2 mm and intraradicular reinforcement using Splendor-SAP; G6 - With root remnant of 3 mm and intraradicular reinforcement using Splendor-SAP. For simulated embrittlement, root wear was 12 mm inside the canal. Then, the specimens were obturated and had the obturator material removed from the cervical and middle thirds, leaving only 4 mm of material in the apical third. The cementation of the posts was performed following the manufacturer's protocol. The fatigue test was carried out by mechanical cycling of the specimens for their aging (1200000 cycles; 3.8 Hz; load = 88 N). The compression test was carried out using the Universal Testing machine, with a load of 100 kg at a speed of 1 mm/min with an incidence of 45°. The average fracture resistance values found for the groups, in ascending order, were: G1 - 9,045 kgf, G2 - 9,753 kgf, G3 - 68,411 kgf, G4 - 80,167 kgf, G5 - 70,551 e G6 - 80,027. The specimens were analyzed under a stereomicroscope to classify the failure mode. The results obtained were submitted to statistical analysis (ANOVA and Tukey) which showed a statistically significant difference (p <0.05). (AU)


Assuntos
Análise de Variância , Análise de Elementos Finitos , Pinos Dentários , Resistência à Flexão
3.
Rev. cuba. estomatol ; 57(4): e3076, Oct.-Dec. 2020. tab
Artigo em Português | LILACS, CUMED | ID: biblio-1144450

RESUMO

Resumo Introdução: Os pinos de fibra de vidro têm sido amplamente utilizados na reconstrução de elementos com perda excessiva de estrutura dentária. Objetivo: Avaliar a força de adesão de pinos de fibra de vidro após diferentes tratamentos radiculares em diferentes regiões (terço cervical, médio e apical) da dentina radicular. Métodos: Este é um estudo experimental in vitro. Quarenta dentes bovinos foram selecionados, preparados e distribuídos em quatro grupos de acordo com o tratamento de superfície utilizado: adesivo (1), agente quelante (2), ácido poliacrílico (3), não tratado (4). A cimentação dos pinos de fibra de vidro foi realizada com cimento resinosante autocondicionante. Após vinte dias, cada raiz foi cortada em três fatias (um milímetro de espessura) obtidas de três regiões. A resistência de união de cada seção foi determinada usando um teste de resistência da junta de encaixe. Os dados de resistência à flexão (MPa) foram analisados pelos testes ANOVA e Tukey (α = 0,05). Resultados: Na porção cervical, o grupo com tratamento prévio com ácido poliacrílico apresentou menor resistência ao cisalhamento por extrusão (push-out) do que o grupo sem tratamento prévio. O grupo com aplicação do sistema adesivo (28,89 ± 6,64 MPa) e o grupo com tratamento prévio com EDTA (21,58 ± 6,39 MPa) não apresentaram diferenças estatisticamente significantes em relação ao grupo sem tratamento prévio (grupo controle) no terço cervical. Nas porções média e apical, o grupo tratado com adesivo FGM Ambar apresentou maiores valores de ligação em comparação com os outros grupos. Conclusão: A aplicação prévia do adesivo aumentou a resistência de união nos terços médio e apical, em comparação aos outros grupos, podendo ter um efeito benéfico no sucesso clínico do tratamento restaurador(AU)


Resumen Introducción: Los postes de fibra de vidrio se han utilizado ampliamente en la reconstrucción de elementos con pérdida excesiva de estructura dental. Objetivo: Evaluar la fuerza de adhesión de postes de fibra de vidrio después de distintos tratamientos de raíz en diferentes regiones (tercios cervical, medio y apical) de dentina de raíz. Métodos: Estudio experimental in vitro. Se seleccionaron cuarenta dientes bovinos, se prepararon y se distribuyeron en cuatro grupos de acuerdo con el tratamiento de superficie utilizado: (1) adhesivo, (2) agente quelante, (3) ácido poliacrílico, (4) sin tratar. La cementación de los postes de fibra de vidrio se realizó con cemento de resina autograbante. Después de 20 días, cada raíz se seccionó transversalmente en tres rodajas (1 mm de espesor) obtenidas de tres regiones. La resistencia a la unión de cada sección se determinó usando una prueba de resistencia al corte por extrusión (push-out). Los datos de resistencia a la flexión (MPa) se analizaron mediante pruebas ANOVA y Tukey (α = 0,05). Resultados: En la porción cervical, el grupo con tratamiento previo de ácido poliacrílico mostró menor resistencia que el grupo sin tratamiento previo. El grupo con aplicación del sistema adhesivo (28,89 ± 6,64 MPa) y el grupo con tratamiento previo de EDTA (21,58 ± 6,39 MPa) no presentaron diferencias estadísticamente significativas en comparación con el grupo sin tratamiento previo (grupo control) en el tercio cervical. En las porciones media y apical, el grupo tratado con adhesivo Ambar® de FGM Dental Group mostró valores más altos de unión en comparación con los otros grupos. Conclusión: La aplicación previa del adhesivo aumentó la fuerza de unión en los tercios medio y apical, en comparación con los otros grupos, puede tener un efecto beneficioso sobre el éxito clínico del tratamiento restaurador(AU)


ABSTRACT Introduction: Glass fiber posts have been widely used for the reconstruction of elements with excessive dental structure loss. Objective: Evaluate the bond strength of glass fiber posts after various root dentin treatments in different regions (cervical, middle and apical thirds). Methods: An experimental in vitro study was conducted. Forty bovine teeth were selected, prepared and distributed into four groups according to the surface treatment used: (1) adhesive, (2) chelating agent, (3) polyacrylic acid, (4) not treated. The glass fiber posts were cemented with self-etch resin cement. After 20 days, each root was sectioned crosswise into three slices (1 mm in thickness) obtained from three regions. Bond strength was determined in each section with a push-out bond strength test. Flexural strength data (MPa) were analyzed with ANOVA and Tukey's tests. Results: In the cervical portion, the group with previous polyacrylic acid treatment displayed lower push-out strength than the group without previous treatment. The group with application of the adhesive system (28.89 ± 6.64 MPa) and the group with previous EDTA treatment (21.58 ± 6.39 MPa) did not exhibit any statistically significant differences in comparison with the group without previous treatment (control group) in the cervical third. In the middle and apical portions, the group treated with the adhesive Ambar® of FGM Dental Group showed higher bond values in comparison with the other groups. Conclusion: Previous adhesive application increased bond strength in the middle and apical thirds in comparison with the other groups, and may thus have a beneficial effect on the clinical success of the restorative treatment(AU)


Assuntos
Humanos , Reabsorção da Raiz/terapia , Preparo de Canal Radicular/métodos
4.
Arq. odontol ; 56: 1-8, jan.-dez. 2020. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1097768

RESUMO

Aim: To evaluate the influence of lengths and different luting agents on the bond strength of fiberglass posts' adhesion to dentin.Methods: Sixty single-root bovine teeth were endodontically treated and included in polyether and acrilyc resin to simulate a periodontal ligament. These were divided into 6 groups according to the post lengths (6, 10 or 14 mm) and luting agents (self-adhesive dual resin cement ­ U; or etch-and-rinse dual resin cement ­ A): U6, U10, U14, A6, A19, and A14. All fiberglass posts were cemented according to manufacturer instructions. After this, mechanical aging was performed (1.2x106 cycles; 4 Hz, 90 N). The push-out specimens were then conducted (2.0 ± 0.1 mm), with the test executed in a universal machine (10 kgf at 0.5 mm/min). Data obtained were submitted to the Kruskal-Wallis and Dunn's test. Results: No statistically significant difference was observed in bond strength between the groups due to the type of luting agent (p > 0.05). However, the isolated post-length factor showed significantly different results for the U groups (p < 0.05). The U10 group showed similar union values to U6 but statistically inferior to U14. Conclusion: bond strength of fiberglass posts of the same length as the dentin presented no differences according to the luting agent, but the post-length property influenced the bond strength when self-adhesive resin cement was used.


Objetivo: avaliar a influência dos agentes cimentantes e dos diferentes comprimentos de pinos na resistência de união de pinos de fibra de vidro a dentina. Métodos: Sessenta dentes bovinos uniradiculares tiveram a raiz endodonticamente tratada, e foram incluídos em poliéter e resina acrílica para simular o ligamento periodontal. Os espécimes foram divididos em seis grupos de acordo com o comprimento dos pinos (6, 10 ou 14mm) e dos agentes de cimentantes (cimento resinoso dual autoadesivo (RelyX U200, 3M ESPE) - U; ou cimento resinoso dual convencional (AllCem Core, FGM) - A: U6, U10, U14, A6, A19 e A14. Todos os pinos de fibra de vidro foram cimentados conforme as recomendações do fabricante. Após, o envelhecimento mecânico (1,2x106 ciclos; 4 Hz, 90 N) as amostras foram fatiadas para o teste de push-out (2,0 ± 0,1 mm) executado em uma máquina de ensaio universal (10 kgf a 0,5 mm/min). Os dados foram submetidos ao teste de Kruskal-Wallis e Dunn. Resultados: não houve diferença estatística na resistência de união entre os grupos devido ao tipo de agente cimentante (p > 0,05), mas houve para o comprimento dos pinos dos grupos U (p < 0,05). O grupo U10 apresentou valores de união semelhantes a U6, mas estatisticamente inferiores ao U14. Conclusão: a resistência de união dos pinos de fibra de vidro de um mesmo comprimento não apresentou diferenças mesmo quando cimentados com cimentos diferentes, mas o comprimento dos pinos isoladamente influenciou quando o cimento resinoso autoadesivo foi utilizado.


Assuntos
Resinas Acrílicas , Teste de Materiais , Cimentos de Resina , Cimentos Dentários , Ciência dos Materiais , Cimentos de Ionômeros de Vidro , Pinos Dentários
5.
São José dos Campos; s.n; 2019. 60 p. il., tab., graf..
Tese em Português | BBO - Odontologia | ID: biblio-969240

RESUMO

O objetivo deste trabalho foi avaliar, in vitro, pelo teste de compressão, a resistência à fratura de dentes fragilizados que receberam como reforço intra-radicular sistema de pino de fibra de vidro. Foram utilizados 80 dentes bovinos divididos de acordo com o tipo de reforço intra-radicular e com a presença ou não de preparos para simular fragilidade radicular (n=10): SF/SR - sem fragilização e sem reforço intra- radicular; F/SR - com fragilização e sem reforço intra-radicular; SF/GT - sem fragilização e com reforço intra-radicular Rebilda Post GT; F/GT ­ com fragilização e com reforço intraradicular Rebilda Post GT; SF/RP - sem fragilização e com reforço intra-radicular Rebilda Post; F/RP ­ com fragilização e com reforço intra-radicular Rebilda Post; SF/GT+RP - sem fragilização e com reforço intra-radicular Rebilda Post GT + Rebilda Post; e F/GT+RP ­ com fragilização e com reforço intra-radicular Rebilda Post GT + Rebilda Post. Todos os espécimes tiveram suas coroas seccionadas, comprimento radicular padronizado em 16 mm e canais radiculares preparados endodonticamente. Para os espécimes com fragilização simulada, o desgaste radicular foi realizado até 9 mm no interior do canal e a espessura do remanescente radicular obtida foi de aproximadamente 2 mm. Exceto para o SF/SR, todos os canais radiculares foram obturados. O material obturador foi removido dos terços cervical e médio, permanecendo apenas 4 mm no terço apical. A cimentação dos pinos foi realizada seguindo o protocolo do fabricante. Apenas para os espécimes dos grupos SF/GT+RP e F/GT+RP, após a inserção do pino Rebilda Post GT e antes da polimerização final, foi inserido no centro do conjunto o pino Rebilda Post. Os espécimes foram submetidos ao teste de compressão à 45º. Os valores de resistência à fratura encontrados para os grupos, em ordem decrescente, foram: F/SR ­ 5,045 kgf, SF/SR ­ 9,157 kgf, SF/GT ­ 14,032 kgf, F/RP ­ 27,727 kgf, F/GT ­ 28,303 kgf, SF/RP ­ 29,986 kgf, F/GT+RP ­ 38,650 kgf e SF/GT+RP ­ 39,783 kgf. Os resultados obtidos foram submetidos à análise estatística (ANOVA e Tukey) que demonstrou diferença estatisticamente significativa (p<0,05). Dessa forma observouse que o pino único, Rebilda Post, proporcionou maior resistência à fratura que o sistema Rebilda Post GT e os grupos sem reforço intra-radicular, SF/SR e F/SR; e que a associação dos sistemas produziu os maiores valores de resistência à fratura do que os demais(AU)


The objective of this work was to evaluate, in vitro, by the compression test, the fracture strength of fragile teeth that received a fiberglass pin system as intra- radicular reinforcement. It was used 80 bovine teeth divided according to the type of intraradicular reinforcement and with the presence or not of preparations to simulate root fragility (n = 10): SF / SR - without embrittlement and without intra-radicular reinforcement; F / SR - with embrittlement and without intra-radicular reinforcement; SF / GT - without embrittlement and with intra-radicular reinforcement Rebilda Post GT; F / GT - with embrittlement and intra-radicular reinforcement Rebilda Post GT; SF / RP - without embrittlement and with intra-radicular reinforcement Rebilda Post; F / RP - with embrittlement and intra-radicular reinforcement Rebilda Post; SF / GT + RP - without embrittlement and with intra-radicular reinforcement Rebilda Post GT + Rebilda Post; and F / GT + RP - with embrittlement and with intra-radicular reinforcement Rebilda Post GT + Rebilda Post. All specimens had their crowns sectioned, root length standardized at 16 mm and root canals prepared endodontically. For specimens with simulated embrittlement, root wear was performed up to 9 mm inside the canal and the thickness of the root remainder obtained was approximately 2 mm. Except for SF / SR, all root canals were filled. The obturator material was removed from the cervical and middle thirds, remaining only 4 mm in the apical third. Pin cementation was performed following the manufacturer's protocol. Only for the specimens of the groups SF / GT + RP and F / GT + RP, after the insertion of the Rebilda Post GT pin and before the final polymerization, the Rebilda Post pin was inserted in the center of the set. The specimens were submitted to the 45º compression test. The values of fracture resistance found for the groups, in descending order, were: F / SR - 5,045 kgf, SF / SR - 9,157 kgf, SF / GT - 14,032 kgf, F / RP - 27,727 kgf, F / GT - 28,303 kgf, SF / RP-29.986 kgf, F / GT + RP-38.650 kgf and SF / GT + RP-39.783 kgf. The results were submitted to statistical analysis (ANOVA and Tukey), which showed a statistically significant difference (p< 0,05). In this way, it was observed that the single post, Rebilda Post, provided greater resistance to fracture than the Rebilda Post GT system and the non-reinforced groups, SF / SR and F / SR; and that the association of the systems produced the highest values of fracture resistance than the others(AU)


Assuntos
Humanos , Pinos Dentários , Raiz Dentária/diagnóstico por imagem
6.
J. res. dent ; 6(1): 16-22, jan.-feb2018.
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1358810

RESUMO

A restauração ideal de um dente compreende devolver a função, a estética e a preservação do remanescente dentário, contudo, um sistema retentor que atenda às necessidades endodônticas e proporcione uma adesão adequada é um dos maiores desafios da odontologia restauradora. Há um aumento do uso clínico de pinos de fibra de carbono e de vidro, pois além de não sofrerem corrosão, permitem um preparo conservador do tecido dental e apresentam um bom resultado estético. Além disso, se comparado com os núcleos metálicos fundidos, esses sistemas de pinos intra-radiculares de fibra diminuem o tempo clínico e não precisam do laboratório de prótese para a fabricação. Em dentes extensamente destruídos a restauração convencional tem se mostrado insatisfatórias quando comparadas a próteses de coroa total, nesses casos faz-se necessário algum tipo de retenção intra-canal como pinos e núcleos com cimentação de coroa artificial. O sistema de pinos-núcleos fundidos metálicos foram os mais populares sendo considerado "padrão ouro", devido aos percentuais de sucesso superior. São considerados ideais pela resistência e versatilidade. Os pinos pré-fabricados metálicos ou de fibra, tanto cônicos como paralelos oferecem boas retenção para restauração coronária, porém os paralelos já estão em desuso. Os pinos de fibra de vidro, por serem um tanto frágeis são recomendados em casos com mais de 50% de remanescente, quantidade recomendada também para pinos cerâmicos. Também em relação ao uso de pinos pré-fabricados, ressaltam que o diâmetro do conduto e do canal deve ser compatível, já que a dentina remanescente não deve ser diminuída a ponto de reduzir a resistência da raiz. Definitivamente deve-se considerar a quantidade de estrutura mineralizada e a possibilidade de abraçamento cervical de pelo menos 2mm cervical ao núcleo. Este efeito de abraçamento que muitos trabalhos sugerem aumenta a resistência do remanescente, preserva a integridade do selamento marginal e reduz o estresse na junção cemento núcleo. Sendo assim, todos e qualquer sistema podem apresentar ótimos resultados, desde que usados conforme sua indicação e bom senso em cada caso, respeitado comprimento e diâmetro ideais conservando ao máximo a estrutura dentária.

7.
São José dos Campos; s.n; 2015. 78 p. ilus, tab, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-867652

RESUMO

O objetivo no presente estudo foi avaliar, in vitro, a influência do comprimento do pino de fibra de vidro na resistência à fratura de raízes submetidas a diferentes níveis de fragilização. Noventa incisivos bovinos, de dimensões semelhantes, tiveram as coroas removidas e foram instrumentados, obturados e divididos aleatoriamente em 9 grupos (n =10), de acordo com o protocolo de fragilização (SF - sem fragilização; FM - fragilização moderada; FS - fragilização severa) e o comprimento do pino utilizado (7 mm; 9 mm e 12 mm). Os canais foram preparados para o retentor e, nas raízes fragilizadas, os mesmos foram individualizados com resina composta. Foi utilizado um cimento resinoso quimicamente ativado para a cimentação de todos os pinos. Após a cimentação, foi feita reconstrução coronária com resina composta, com base em matrizes de silicone padronizadas. Para reprodução da mobilidade fisiológica, a porção radicular foi coberta com poliéter e incluída em poliuretano. A ciclagem termomecânica foi realizada sob cargas de 88 N em 1.200.000 ciclos, com frequência de 3,8 Hz. Para determinação da resistência à fratura, as amostras foram posicionadas a 45 ° em uma máquina de ensaios universal, com célula de carga de 100 Kgf e velocidade de 1 mm/min. Após o ensaio mecânico, os espécimes foram analisados em estereo microscópio para classificação do tipo de fratura gerada (reparável/irreparável). Os valores de resistência obtidos foram submetidos a análise estatística ANOVA – dois fatores e teste de Tukey (nível de significância de 5%). As frequências dos tipos de fratura foram comparadas pelo teste qui-quadrado. Os resultados da ANOVA revelaram que a associação entre o comprimento do pino e a fragilização foi estatisticamente significante (p < 0,05). O teste de Tukey indicou que esta diferença foi entre as raízes não fragilizadas e com maior nível de fragilização, quando utilizado o pino de 12 mm de comprimento. O teste qui-quadrado indicou que houve ...


The aim in this study was to evaluate, in vitro, the influence of glass fiber posts of different lengths on the fracture resistance of roots submitted to different weakening protocols. Ninety bovine roots, of same dimensions, were endodontically treated and randomly distributed in 9 groups (n =10), according the weakening protocol (NW – non-weakened; MW - medium-weakened; HW – hard-weakened) and the post length (7 mm; 9 mm e 12 mm). The canals were prepared for the posts and, on the weakened roots, they were individualized with composite resin A chemically activated resin cement was used in all posts. After luting, coronary reconstruction was conducted with composite resin, based on standardized silicon matrix. To reproduce physiological mobility, root portion was covered by polyether and embedded in polyurethane. The thermomechanical cycling was realized under a load of 88 N at 1.200.000 cycles, with a frequency of 3.8 Hz. For the resistance of fracture analysis, the specimens were placed at 45 ° in a universal testing machine, with a load-cell of 100 Kgf, with speed of 1mm/min. After mechanical essay, the specimens were analyzed by stereomicroscope to classify the failure mode (reparable/irreparable). Numerical values (n = 10) obtained for specimens’ fracture were subjected to statistical analysis ANOVA two-way and Tukey test (5% of significance). The frequencies of failure mode were compared by chi-square test. ANOVA showed that the association between length and weakening was statistically significant (p < 0.05). The post-hoc Tukey’s test revealed that this difference was between NW and HW roots for posts of 12-mm in length. Chi-square test indicated association between failure mode and the length and weakening factors. It was concluded that highly-weakened roots with longer posts had lower fracture resistance values, as catastrophic mode was more predominant


Assuntos
Pinos Dentários , Teste de Materiais
8.
Braz. dent. sci ; 18(4): 19-24, 2015. tab
Artigo em Inglês | LILACS | ID: lil-786316

RESUMO

The aim of the present study was to compare the effects of Nd:YAG laser application in root canals on bond strengths of fiber posts.Material and Methods: Thirty single-rooted bovines were randomly divided into three groups (n = 10); root canal instrumentation was performed, and pretreatment was conducted as follows: C group: conventional treatment (without laser irradiation); ALC group: Nd:YAG laser was applied after adhesive; and LAC group: Nd:YAG laser was applied before adhesive. The fiber posts Rebilda 15 DC (Voco) were cemented with an adhesive system and resin cement,in accordance with the manufacturer’s instructions. Six slices with 1.0mm height was obtained for ofeach root and bond strength was measured by pushout test using a universal testing machine (0.5 mm/min). Data were analyzed using Kruskal-Wallis and Dunn’s tests (p < 0.05). Results: Push-out bond strengths to root canal dentin were affected by the type of treatment and root third. The use of Nd: YAGlaser after the application of adhesive system had ahigher bonding performance compared with the useof laser before the application. However, both of them were similar to the control group. Also, cervical and medium third presented higher bond strength values than the apical third. Conclusion: It must be conclude, in the conditions in which the studywas conduct, that the use of laser irradiation didnot improve the bonding performance of resinous cement inside the root canal...


Objective: O objetivo deste estudo foi comparar o efeito da aplicação intrarradicular do laser Nd:YAG na adesão de pinos de fibra de vidro. Material e Métodos: Trinta raízes unirradiculares de incisivos bovinos foram selecionadas, e após instrumentação, foram divididas aleatoriamente em três grupos (n= 10) de acordo com o tratamento das paredes do canal: C: tratamento convencional (sem radiação laser), ALC: aplicação do Laser Nd:YAG após o adesivo; e LAC: aplicação do laser antes do adesivo. Pinos de fibra de vidro Rebilda 15 DC (Voco) foram cimentados com adesivo e cimento resinoso de acordo com instruções do fabricante. Seis fatias (duas para cada terço radicular) com 1 mm de espessura foram obtidas de cada raiz para mensuração da resistência adesiva por meio de teste push-out realizado em máquina de ensaio universal (0,5 mm/min). Os dados foram analisados por meio dos testes Kruskal-Wallis e Dunn (p < 0,05). Resultados: A resistência adesiva dos pinos na dentina radicular foi influenciada pelo tipo de tratamento e terço radicular. O uso do laser de Nd:YAG após a aplicação do adesivo apresentou melhor performance comparada ao seu uso antes do adesivo, porém, ambos foram similares ao controle. Ainda, os terços cervical e médio apresentaram maior resistência comparado ao apical. Conclusão: Conclui-se que, ouso da irradiação laser nos parâmetros estudados, não melhora a performance adesiva de cimentos resinosos dentro do canal radicular...


Assuntos
Animais , Bovinos , Pinos Dentários , Lasers de Estado Sólido , Materiais Restauradores do Canal Radicular
9.
São José dos Campos; s.n; 2015. 78 p. ilus, tab, graf.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-870228

RESUMO

O objetivo no presente estudo foi avaliar, in vitro, a influência do comprimento do pino de fibra de vidro na resistência à fratura de raízes submetidas a diferentes níveis de fragilização. Noventa incisivos bovinos, de dimensões semelhantes, tiveram as coroas removidas e foram instrumentados, obturados e divididos aleatoriamente em 9 grupos (n =10), de acordo com o protocolo de fragilização (SF - sem fragilização; FM - fragilização moderada; FS - fragilização severa) e o comprimento do pino utilizado (7 mm; 9 mm e 12 mm). Os canais foram preparados para o retentor e, nas raízes fragilizadas, os mesmos foram individualizados com resina composta. Foi utilizado um cimento resinoso quimicamente ativado para a cimentação de todos os pinos. Após a cimentação, foi feita reconstrução coronária com resina composta, com base em matrizes de silicone padronizadas. Para reprodução da mobilidade fisiológica, a porção radicular foi coberta com poliéter e incluída em poliuretano. A ciclagem termomecânica foi realizada sob cargas de 88 N em 1.200.000 ciclos, com frequência de 3,8 Hz. Para determinação da resistência à fratura, as amostras foram posicionadas a 45 ° em uma máquina de ensaios universal, com célula de carga de 100 Kgf e velocidade de 1 mm/min. Após o ensaio mecânico, os espécimes foram analisados em estereo microscópio para classificação do tipo de fratura gerada (reparável/irreparável). Os valores de resistência obtidos foram submetidos a análise estatística ANOVA – dois fatores e teste de Tukey (nível de significância de 5%). As frequências dos tipos de fratura foram comparadas pelo teste qui-quadrado. Os resultados da ANOVA revelaram que a associação entre o comprimento do pino e a fragilização foi estatisticamente significante (p < 0,05). O teste de Tukey indicou que esta diferença foi entre as raízes não fragilizadas e com maior nível de fragilização, quando utilizado o pino de 12 mm de comprimento. O teste qui-quadrado indicou que houve...


The aim in this study was to evaluate, in vitro, the influence of glass fiber posts of different lengths on the fracture resistance of roots submitted to different weakening protocols. Ninety bovine roots, of same dimensions, were endodontically treated and randomly distributed in 9 groups (n =10), according the weakening protocol (NW – non-weakened; MW - medium-weakened; HW – hard-weakened) and the post length (7 mm; 9 mm e 12 mm). The canals were prepared for the posts and, on the weakened roots, they were individualized with composite resin A chemically activated resin cement was used in all posts. After luting, coronary reconstruction was conducted with composite resin, based on standardized silicon matrix. To reproduce physiological mobility, root portion was covered by polyether and embedded in polyurethane. The thermomechanical cycling was realized under a load of 88 N at 1.200.000 cycles, with a frequency of 3.8 Hz. For the resistance of fracture analysis, the specimens were placed at 45 ° in a universal testing machine, with a load-cell of 100 Kgf, with speed of 1mm/min. After mechanical essay, the specimens were analyzed by stereomicroscope to classify the failure mode (reparable/irreparable). Numerical values (n = 10) obtained for specimens’ fracture were subjected to statistical analysis ANOVA two-way and Tukey test (5% of significance). The frequencies of failure mode were compared by chi-square test. ANOVA showed that the association between length and weakening was statistically significant (p < 0.05). The post-hoc Tukey’s test revealed that this difference was between NW and HW roots for posts of 12-mm in length. Chi-square test indicated association between failure mode and the length and weakening factors. It was concluded that highly-weakened roots with longer posts had lower fracture resistance values, as catastrophic mode was more predominant.


Assuntos
Pinos Dentários , Teste de Materiais
10.
Rev. bras. odontol ; 71(1): 85-88, Jan.-Jun. 2014.
Artigo em Português | LILACS | ID: lil-744269

RESUMO

O objetivo deste estudo foi de verificar, por meio de revisão de literatura, os resultados do tratamento de diferentes superfícies de interesse para a Odontologia com gás argônio, um plasma frio à pressão atmosférica. Este vem sendo recentemente estudado e aplicado com o intuito de aumentar a molhabilidade do substrato condicionado, como zircônia, um material conhecidamente ácido resistente; dentina e pinos de fibra de vidro, interferindo positivamente na adesão. Diferentes estudos foram revisados, podendo-se concluir que o condicionamento com plasma frio de argônio alterou a superfície dos substratos testados, aumentando a área de superfície e, com isso, reduzindo o ângulo de contato. Isto contribui para uma maior molhabilidade do substrato e aumento da adesão às superfícies testadas.


The aim of this study was to verify, by means of literature review, the results of treatment of different areas of interest to Dentistry with Argon gas, a cold atmospheric pressure plasma. This subject has recently been studied and applied in order to increase the wettability of the substrate conditioning as zirconia, a well known acid-resistant material; Pins and dentin fiberglass positively interfering in adhesion. Different studies were reviewed, and shall be concluded that conditioning with cold argon plasma altered the surface of substrates, increasing the surface area and thereby reducing the contact angle. This contributes to a greatter wettability of the substrate and increased adherence to surfaces tested.


Assuntos
Argônio , Zircônio , Pinos Dentários , Dentina
11.
Rio de janeiro; s.n; 2014. 72 p. ilus.
Tese em Português | BBO - Odontologia, LILACS | ID: biblio-1016762

RESUMO

Comparar a força de adesão por meio de ensaios de cisalhamento por extrusão ("push out") de pinos intrarradiculares de fibra de vidro em canais obturados com os cimentos endodônticos Pulp Canal Sealer EWT® e AHPlus® pelas técnicas de compactação lateral e da onda contínua da guta percha termoplastificada. Foram selecionadas 60 raízes de molares inferiores que foram distribuídas aleatoriamente em 04 grupos com 15 amostras cada: Grupo I, técnica da compactação lateral da guta-percha associada ao cimento Pulp Canal Sealer EWT ®; Grupo II, técnica da compactação lateral da guta-percha associada ao cimento AHPlus®; Grupo III, técnica da onda contínua da guta-percha termoplastificada associada ao cimento Pulp Canal Sealer EWT ®; Grupo lV ­ técnica da compactação de onda contínua da guta-percha termoplastificada associada ao cimento AHPlus®. O pino de Fibra de vidro Whitepost DC® 0,5 foi cimentado com sistema adesivo AMBAR® e com o cimento AllCEM® na proporção 1:1 em todas as raízes. Os ensaios de resistência por extrusão foram realizados em três diferentes níveis: cervical, médio e apical, na máquina de ensaio universal EMIC DL 200 MF, à velocidade de 1,0 mm/min, até a fratura. Para análise dos resultados foram utilizados os testes Kruskal-Wallis, Bonferroni e Wilcoxon. Os quatro grupos avaliados foram significativamente diferentes em relação à força máxima do ensaio "push out" (p< 0,000), sendo os grupos IV e III com maior forca de resistência seguidos pelos grupos II e I. Na analise pareada, só não houve diferença estatisticamente significante entre os grupos I e II (p=0,075) e III e IV (p=0,052). Quando o "push out" dos grupos foi comparado por terços, nos terços cervical, médio e apical, os grupos IV e III foram significantemente maiores do que os grupos II e I (p= 0,00, para todas as comparações). Na comparação da força de cisalhamento dentro de cada grupo, a força máxima de "push out" no grupo IV foi significativamente maior em seu terço cervical quando comparado ao terço médio (p= 0,017), mas não foi observada diferença entre os terços médio e apical. Nos outros três grupos, não houve diferença de push out entre os terços. A técnica de obturação dos canais radiculares da onda contínua da guta percha termoplastificada foi superior à técnica da compactação lateral da guta-percha na aplicação de força de cisalhamento ("push out"). O tipo de cimento obturador dos canais radiculares, não exerceu influência na força máxima do "push out" do pino de fibra.


To compare the adhesion strength by push out test of fiberglass intracanal posts filled with Pulp Canal Sealer EWT ® and AHPlus® sealers the techniques of cold lateral compaction and continuous wave of condensation. Sixty roots of mandibular molars were selected and randomly distributed into 04 groups with 15 sample each: Group I, cold lateral compaction technique of gutta-percha associated with Pulp Canal Sealer EWT ® cement, Group II, cold lateral compaction technique of gutta-percha associated with AHPlus®, Group III, continuous wave of condensation technique of gutta-percha associated with cement Pulp Canal Sealer EWT ®; group IV - continuous wave of condensation technique associated with AHPlus®. The Fibreglass Whitepost pin DC® 0.5 was cemented with an adhesive system and the AMBAR® AllCEM® cement 1:1 in all roots. Push out test were performed at three different levels: cervical, middle and apical in a universal testing machine EMIC DL 200 MF at a speed of 1.0 mm / min until fracture. To analyze the results, the Kruskal- Wallis, Bonferroni and Wilcoxon tests were used. The four study groups were significantly different in respect to the bond strength of the push out test (p < 0.000), and the groups III and IV had greater force of resistance followed by groups II and I. In paired analyzes, there was no statistically significant difference only between groups I and II (p = 0.075) and between groups III and IV (p = 0.052) . When the push out of the groups was compared by thirds, cervical , middle and apical thirds of groups III and IV were significantly higher than groups I and II (p = 0.00, for all comparisons) . Comparing the bond strength within each group, the maximum push out force in group IV was significantly higher in his cervical third when compared to the middle third (p = 0.017), but there was no difference between the middle and apical thirds. In the other three groups, there was no push out difference between the thirds. The technique of filling of the root canals continuous wave of condensation, was superior to the technique of cold lateral compaction of gutta - percha on the application of shear force (push out) . The type of root canal sealer had no influence on the push out ultimate strength of the fiber pin.


Assuntos
Humanos , Obturação do Canal Radicular/métodos , Técnica para Retentor Intrarradicular , Cimentos de Resina , Fenômenos Biomecânicos , Teste de Materiais , Colagem Dentária , Estatísticas não Paramétricas , Resistência ao Cisalhamento , Dente Molar
12.
Artigo em Português | LILACS | ID: lil-725989

RESUMO

Objetivo: Avaliar a influência de diferentes protocolos de cimentação na resistência de união ao push-out de pinos de fibra cimentados adesivamente à dentina radicular bovina. Método: Os canais de 40 dentes bovinos (comprimento: 16 mm) foram preparados (profundidade: 12 mm) utilizando brocas de preparo (Nº 3, RTD). Cada canal teve sua região apical (4 mm comprimento) incluídas em resina acrílica e as raízes foram divididas em quatro grupos, de acordo com os procedimentos de cimentação(n=10): G1-sistema adesivo de frascos múltiplos com condicionamento total + pino de fibra nº 3; G2-sistema adesivo de frascos múltiplos com condicionamento total + pino de fibra nº 1; G3-sistema adesivo de frascos múltiplos com condicionamento total + pino de fibra no1 + pinos de fibra acessórios; G4-Pinos de fibra nº 3 sem condicionamento total nem procedimentos de união na dentina. Com exceção do grupo G4, a dentina radicular foi tratada com sistema adesivo de frascos múltiplos com condicionamento total (All Bond 2/Bisco). O sistema adesivo foi aplicado utilizando microbrush (Dentsply) e o excesso do material foi removido com pontas de papel absorventes. Os pinos de fibra de quartzo (Macro-Lock Illusion/RTD) foram cimentados à dentina radicular utilizando um cimento resinoso dual (Duolink/Bisco) e, em seguida, foram armazenados em água destilada previamente ao teste mecânico (24 h, 37°C). Cada espécime foi cortada em quatro fatias (1,8 mm de espessura), as quais foram submetidas ao ensaio de push-out em máquina de ensaio universal (1mm/min). Os dados (MPa) foram analisados estatisticamente pela análise de variância (ANOVA-1 fator)...


Resultados: Os valores médios (±DP) obtidos após o ensaio de push-outforam: G1- 5,4±1,3 MPa; G2- 4,2±2,4 MPa; G3-4,6±1,5 MPa; G4-3,3±1,7 MPa. Anova demonstrou não haver significância estatística entre os grupos (p=0,0966). A hipótese foi rejeitada. Conclusão: A resistência de união de pinos de fibra à dentina radicular não foi influenciada pelos protocolos de cimentação avaliados...


Objective: To evaluate the influence of different luting protocols on the push-out bond strength of fiber posts cemented to bovine root dentin. Method: Forty bovine root canals (length: 16 mm) were prepared up to 12 mm using #3 (RTD) preparation burs. Each canal had its apical 4 mm embedded in acrylic resin and the roots were assigned to four groups (n=10), according to the cementation procedures: G1: etch-and-rinse multi-bottle adhesive system + #3 fiber post; G2: etch-and-rinse multibottle adhesive system + #1 fiber post; G3: etch-and-rinse multi-bottle adhesive system + #1 fiber post + accessory fiber posts; G4: #3 fiber post without etching and bonding procedures to dentin. Except for G4, root dentin was treated with the etch-and-rinse multi-bottle adhesive system All Bond 2 (Bisco). The adhesive system was applied with a microbrush (Dentsply) and excess material was removed withabsorbent paper points. The quartz fiber posts (Macro-Lock Illusion/RTD) were cemented to the root dentin with a dual-cure resin cement (Duolink/Bisco) and were stored in distilled water (for 24 h at 37 °C) before the mechanical tests. Each sample was cut into four slices (1.8 mm thick) that were subjected to push-out tests in a universaltesting machine (1 mm/min). The data (in MPa) were analyzed statistically by one-way ANOVA. Results: The mean push-out bond strength values (±SD) were: G1: 5.4 ± 1.3 MPa; G2: 4.2 ± 2.4 MPa; G3: 4.6 ± 1.5 MPa and G4: 3.3 ± 1.7 MPa. One-way ANOVA showed no statistically significant differences among the groups. The tested hypothesis was discarded. Conclusion: The push-out bond strength of fiber posts to root dentin was not influenced by the evaluated luting protocols...


Assuntos
Animais , Bovinos , Dentina , Preparo de Canal Radicular , Resistência à Tração , Análise de Variância
13.
Braz. dent. sci ; 16(4): 84-92, 2013. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-728091

RESUMO

Objective: This study evaluated the effect of root perforations on the bond strength of fiberglass posts cemented to the root canal with two adhesive systems and resin cement. Material and Methods: Forty single-rooted human teeth received endodontic treatment and were prepared for the cementation of fiberglass posts (Exacto Mini, Angelus). The teeth were divided into four experimental groups (n = 10) according to the root condition (with or without perforation) and the adhesive system used: G1: without perforation + Adper Single Bond 2 (3M ESPE), G2: without perforation + Clearfil SE Bond (Kuraray), G3: with perforation + Adper Single Bond 2, G4: with perforation + Clearfil SE Bond. The perforation was executed on the root surface with a diamond bur and sealed with white mineral trioxide aggregate (MTA). The specimens were sectioned and a push-out test was carried out (1 mm/min speed and 50 kgf). The data were statistically analyzed by ANOVA and Tukey Test (5%). Results: Adper Single Bond 2 promoted the greatest values of bond strength to the roots without root perforation. The presence of root perforation led to the reduction in bond strength values regardless of the bonding system used (p < 0.05). Conclusion: The root perforations caused a direct effect on the bond strength of the fiberglass posts cemented by reducing the bond strength values to the root dentin regardless of the adhesive system used.


Objetivo: O objetivo deste estudo foi avaliar o efeito das perfurações radiculares na resistência de união de pinos de fibra de vidro cimentados com dois sistemas adesivos e um cimento resinoso. Material e Métodos: Quarenta dentes humanos unirradiculares receberam tratamento endodôntico e foram preparados para cimentação de pinos de fibra de vidro (Exacto Mini, Angelus). Os dentes foram divididos em quatro grupos experimentais (n = 10) de acordo com a condição radicular (com ou sem perfuração) e o sistema adesivo utilizado: G1: sem perfuração + Adper™ Single Bond 2; G2: sem perfuração + Clearfil SE Bond; G3: com perfuração + Adper™ Single Bond 2; G4: com perfuração + Clearfil SE Bond. A perfuração foi realizada na superfície radicular com uma ponta diamantada e selada com agregado de trióxido mineral branco (MTA). Os espécimes foram seccionados para realização do teste de extrusão por cisalhamento (Push-out) com velocidade de 1 mm/ min e célula de carga de 50 Kgf. Os dados obtidos foram submetidos à Análise de Variância (ANOVA) e Teste de Tukey a 5%. Resultados: O sistema adesivo Adper Single Bond 2 promoveu os maiores valores de resistência de união nas raízes sem perfuração radicular. A presença de perfuração promoveu redução nos valores de resistência de união, independentemente do sistema adesivo utilizado (p < 0,05). Conclusão: As perfurações radiculares causaram efeito direto sobre a resistência de união dos pinos de fibra de vidro, promovendo redução nos valores da resistência de união independentemente do tipo de sistema adesivo utilizado.


Assuntos
Humanos , Cimentação , Cimentos Dentários , Adesivos Dentinários
14.
ROBRAC ; 21(58)jul.-set. 2012. ilus
Artigo em Português | LILACS | ID: lil-676051

RESUMO

O protocolo restaurador de dentes tratados endodonticamente é um desafio na odontologia adesiva atual, já que existem vários tipos de retentores intrarradiculares à disposição no mercado, com características ópticas e mecânicas que promovem um tratamento satisfatório. Dessa forma, a técnica de pino de fibra anatômico reembasado com resina composta direta torna-se eficiente para uso na clínica odontológica, especialmente em casos de condutos largos e tamanho reduzido de férula. Para tanto, o pino é limpo, aplica-se o silano e adesivo, além da resina composta não polimerizada para moldar o conduto radicular. Após, o pino é tratado novamente e cimentado com uma pequena espessura de linha de cimentação. Nesse artigo, o caso clinico abordará as etapas necessárias para a confecção do pino anatômico, além das estratégias de cimentação adesiva e a restauração com resina composta, trabalhando os conceitos da manutenção de uma delgada linha de cimentação para uma adequada reabilitação dental mantendo biomecânica e retenção do pino de fibra no interior do conduto radicular.


The restorative protocol for endodontically treated teeth is a challenge in adhesive dentistry, since there are several available types of intracanal posts with optical and mechanical characteristics that promotea satisfactory treatment. Thus, the anatomical fiber post technique is efficient for the use in dental practice, especially in cases of large root canals and small dental ferrules. So, the post is cleaned and then the silaneagent and adhesive system are applied, followed by the placement of the non-polymerized composite for root canal modeling. After this, the anatomical fiber post is treated again and followed by the luting procedure, showing a small cementation thickness. In this paper, the case report will address the necessary steps to realize the anatomical fiber post technique using strategies and adhesive cementation with composite resin restoration, working the concepts of maintaining a thin cement line and an adequate dental rehabilitation.

15.
Rio de Janeiro; s.n; 2012. 54 p. ilus, tab.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-866133

RESUMO

O objetivo deste estudo foi realizar uma avaliação tridimensional da rugosidade superficial em 3 tipos de pinos de fibra - DT LightPost®, FRC Postec Plus® e Transluma Post™ - submetidos a diferentes tratamentos de superfície e avaliar os efeitos dos pré-tratamentos na resistência adesiva a um compósito de presa dual Biscore™. Os tratamentos de superfície foram: imersão em ácido hidrofluorídrico, jateamento com óxido de alumínio a 50µm, imersão em peróxido de hidrogênio, jateamento com óxido de alumínio a 50µm seguido de imersão em ácido hidrofluorídrico e jateamento com óxido de alumínio a 50µm seguido de imersão em peróxido de hidrogênio. No experimento 1, 75 pinos foram divididos em 3 grupos (n = 25), de acordo com seu fabricante e subdivididos em cinco subgrupos. A rugosidade superficial foi medida usando um rugosímetro tridimensional e analisada com o software de análise 3D. Os valores de rugosidade foram obtidos antes e após diferentes tratamentos de superfície na área dos mesmos corpos-de-prova. Para o experimento 2, foram utilizados os mesmos corpos-de-prova, os mesmos grupos e subgrupos do experimento 1, tendo sido adicionado o subgrupo de controle (n=90) e a resistência adesiva a um compósito presa dual Biscore™ foi mensurada através de um teste push-out. A resistência adesiva foi medida em uma máquina universal de ensaios, com uma célula de carga tipo SLBL-5kN em uma velocidade de 0,5 mm / min. Os resultados do experimento 1 foram analisados através de um teste estatístico t-Student. Jateamento e jateamento seguido de imersão em ácido hidrofluorídrico produziram um aumento estatisticamente significante na rugosidade, contudo somente o tratamento por jateamento proporcionou um aumento significativo nos valores de rugosidade. Os resultados do experimento 2 foram obtidos através de um um teste t-unilateral de hipótese com variância desconhecida. Concluiu-se que o jateamento com óxido de alumínio a 50μm em uma distância de 30 mm a 2,5 bar ...


The aim of this study was to perform a tridimensional surface roughness test evaluation of different surface treatments to 3 types of fiber posts - DT LightPost®, FRC Postec Plus® e Transluma Post™ - and evaluate the effects of the different pretreatments on the bond strength of a dual-cure resin core material Biscore™. The different surface treatments were: immersion in hydrofluoric acid, sandblasting abrasion with 50 µ alumina particles, immersion in hydrogen peroxide, sandblasting abrasion with 50 µ alumina particles followed by immersion in hydrofluoric acid and sandblasting abrasion with 50 µ alumina particles followed by immersion in hydrogen peroxide. In the first experiment seventy five fiber posts were divided into 3 groups (n = 25), according to their manufacturer and subdivided into 5 subgroups. Surface roughness was measured using a tridimensional surface roughness test and analyzed with 3D analysis software. Surface roughness was obtained before and after the different surface treatments at the same post area. In the second experiment the same samples divided in groups and subgroups were used, but a control group (no treatment) was added (n = 90) and the bond strength to a composite resin core material Biscore™ was measured using a push-out design. The interfacial push-out bond strength was measured in a universal testing machine, with a load cell type SLBL-5kN at a crosshead speed of 0.5 mm/min. Results in experiment 1 were statistically analyzed using Student´s t-Test. Sandblasting and sandblasting followed by immersion in hydrofluoric acid produced a significant increase in roughness, but the sandblasting treatment was able to provide a significant roughness increase. Results in experiment 2 were statistically analysed using one-sided t-Test of Hypothesis with unknown variance. It was concluded that sandblasting airborne-particle abrasion with alumina 50µ at a distance of 30 mm at 2.5 bars pressure for 5 seconds was ...


Assuntos
Resinas Compostas , Pinos Dentários , Adesividade , Óxido de Alumínio , Peróxido de Hidrogênio , Propriedades de Superfície , Autocura de Resinas Dentárias
16.
Rio de Janeiro; s.n; 2012. 54 p. ilus, tab.
Tese em Português | LILACS, BBO - Odontologia | ID: lil-673664

RESUMO

O objetivo deste estudo foi realizar uma avaliação tridimensional da rugosidade superficial em 3 tipos de pinos de fibra - DT LightPost®, FRC Postec Plus® e Transluma Post™ - submetidos a diferentes tratamentos de superfície e avaliar os efeitos dos pré-tratamentos na resistência adesiva a um compósito de presa dual Biscore™. Os tratamentos de superfície foram: imersão em ácido hidrofluorídrico, jateamento com óxido de alumínio a 50µm, imersão em peróxido de hidrogênio, jateamento com óxido de alumínio a 50µm seguido de imersão em ácido hidrofluorídrico e jateamento com óxido de alumínio a 50µm seguido de imersão em peróxido de hidrogênio. No experimento 1, 75 pinos foram divididos em 3 grupos (n = 25), de acordo com seu fabricante e subdivididos em cinco subgrupos. A rugosidade superficial foi medida usando um rugosímetro tridimensional e analisada com o software de análise 3D. Os valores de rugosidade foram obtidos antes e após diferentes tratamentos de superfície na área dos mesmos corpos-de-prova. Para o experimento 2, foram utilizados os mesmos corpos-de-prova, os mesmos grupos e subgrupos do experimento 1, tendo sido adicionado o subgrupo de controle (n=90) e a resistência adesiva a um compósito presa dual Biscore™ foi mensurada através de um teste push-out. A resistência adesiva foi medida em uma máquina universal de ensaios, com uma célula de carga tipo SLBL-5kN em uma velocidade de 0,5 mm / min. Os resultados do experimento 1 foram analisados através de um teste estatístico t-Student. Jateamento e jateamento seguido de imersão em ácido hidrofluorídrico produziram um aumento estatisticamente significante na rugosidade, contudo somente o tratamento por jateamento proporcionou um aumento significativo nos valores de rugosidade. Os resultados do experimento 2 foram obtidos através de um um teste t-unilateral de hipótese com variância desconhecida. Concluiu-se que o jateamento com óxido de alumínio a 50μm em uma distância de 30 mm a 2,5 bar ...


The aim of this study was to perform a tridimensional surface roughness test evaluation of different surface treatments to 3 types of fiber posts - DT LightPost®, FRC Postec Plus® e Transluma Post™ - and evaluate the effects of the different pretreatments on the bond strength of a dual-cure resin core material Biscore™. The different surface treatments were: immersion in hydrofluoric acid, sandblasting abrasion with 50 µ alumina particles, immersion in hydrogen peroxide, sandblasting abrasion with 50 µ alumina particles followed by immersion in hydrofluoric acid and sandblasting abrasion with 50 µ alumina particles followed by immersion in hydrogen peroxide. In the first experiment seventy five fiber posts were divided into 3 groups (n = 25), according to their manufacturer and subdivided into 5 subgroups. Surface roughness was measured using a tridimensional surface roughness test and analyzed with 3D analysis software. Surface roughness was obtained before and after the different surface treatments at the same post area. In the second experiment the same samples divided in groups and subgroups were used, but a control group (no treatment) was added (n = 90) and the bond strength to a composite resin core material Biscore™ was measured using a push-out design. The interfacial push-out bond strength was measured in a universal testing machine, with a load cell type SLBL-5kN at a crosshead speed of 0.5 mm/min. Results in experiment 1 were statistically analyzed using Student´s t-Test. Sandblasting and sandblasting followed by immersion in hydrofluoric acid produced a significant increase in roughness, but the sandblasting treatment was able to provide a significant roughness increase. Results in experiment 2 were statistically analysed using one-sided t-Test of Hypothesis with unknown variance. It was concluded that sandblasting airborne-particle abrasion with alumina 50µ at a distance of 30 mm at 2.5 bars pressure for 5 seconds was ...


Assuntos
Resinas Compostas , Pinos Dentários , Adesividade , Óxido de Alumínio , Peróxido de Hidrogênio , Propriedades de Superfície , Autocura de Resinas Dentárias
17.
Rev. odontol. UNESP (Online) ; 40(4): 174-181, jul.-ago. 2011. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-614424

RESUMO

O objetivo deste estudo foi avaliar a resistência de união por push-out e o selamento marginal de sistemas adesivos convencionais e autocondicionantes utilizados para cimentação de pinos de vidro intrarradiculares em diferentes profundidades. Noventa raízes de pré-molares humanos (45 para os testes de push-out e 45 para os de microinfiltração) tiveram os canais preparados com profundidades padronizadas e foram aleatoriamente distribuídas em 3 grupos(n = 15) de acordo com o sistema adesivo utilizado: Adper Scotchbond Multi Purpose (3M ESPE); Adper Single Bond 2 (3M ESPE); Clearfil SE Bond (Kuraray). As raízes receberam pino de fibra de vidro com cimento resinoso. Para os testes de push-out, as raízes foram cortadas radialmente em 3 diferentes profundidades para obter cortesseriados de aproximadamente 1 mm de espessura. Uma máquina de ensaios mecânicos (Emic) foi utilizada para os ensaios de push-out. Para os testes de microinfiltração, as raízes foram seladas e imersas em solução de azul de metileno a 2%, pH 7,0 por 2 horas. As raízes foram cortadas radialmente em 3 diferentes profundidades para obter cortes seriados com espessura de 1 mm e a microinfiltração foi avaliada em lupa estereoscópica por 3 examinadores calibrados que atribuíram escores de 0 a 3. A Análise de Variância e o teste de Tukey para os testes de push-out mostraram que não houve diferenças significativas entre os sistemas adesivos (p >0,05), mas houve entre as profundidades, com maiores valores de resistência de união para o terço cervical e apical. Para os ensaios de microinfiltração, os testes de Kruskal-Wallis e de Friedman mostram que não houve diferença significativa entre os adesivos e entre as profundidades (p > 0,05). Os sistemas adesivos convencionais e autocondicionantes apresentaram semelhante resistência de união e de selamento marginal para a cimentação de pinos de fibra de vidro, havendo maior resistência de união nos terços mais cervicais e apicais dos canais.


The aim of this study was to evaluate the push-out bond strength and sealing ability of etch-and-rinse and selfetching adhesives used for fiberglass dowel bonding at different depths of the root canals. Ninety human pre-molar roots (45 for the push-out tests and 45 for the microleakage tests) had their canals prepared with standardized depthsand were randomly allocated into 3 groups (n = 15) according to the adhesive system used: Adper Scotchbond Multi Purpose (3M ESPE); Adper Single Bond 2 (3M ESPE); Clearfil SE Bond (Kuraray). They were restored with fiberglass dowel and resin cement. For the push-out tests, the roots were radially cut at 3 different depths to obtain serial cutswith approximately a thickness of 1 mm. A universal testing machine (Emic) was used for the push-out test. For the microleakage group, roots were sealed, and immersed in a 2% methylene blue solution, pH 7.0, for a 2 hours period. Roots were radially sectioned at 3 different depths to obtain serial cuts with a thickness of approximately 1mm and microleakage was evaluated in stereoscopic loupe by three calibrated evaluators who attributed scores from 0 to 3. The Analysis of Variance and the Tukey test for the push-out tests showed no significant differences among adhesive systems (p > 0.05), but differences among the depths with higher bond strength at the cervical and apical depth.For microleakage, Kruskal-Wallis and Friedman tests showed that there was no significant difference among the adhesive systems tested or different depths of cut (p > 0.05). The total-etching and self-etching adhesive systems had similar bond strength and ability of marginal sealing for the cementation of fiberglass dowels and that higher bond strength was obtained at the most cervical and apical depths of the root canals.


Assuntos
Dente Pré-Molar , Adesivos Dentinários , Cimentos de Resina , Resistência ao Cisalhamento , Infiltração Dentária , Pinos Dentários , Análise de Variância , Estatísticas não Paramétricas
18.
Braz. dent. sci ; 14(1/2): 34-42, 2011. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-642710

RESUMO

O objetivo deste estudo foi avaliar o efeito das perfurações radiculares na resistência adesiva de pinos de fibra de vidro cimentados com dois cimentos resinosos à dentina intra-radicular. Quarenta dentes humanos unirradiculares hígidos receberam tratamento endodôntico e foram preparados para a cimentação de pinos de fibra de vidro (Exacto Mini, Angelus). Os dentes foram divididos em 4 grupos experimentais (n=10) de acordo com a condição radicular (perfuração presente ou ausente) e o cimento resinoso utilizado: G1: perfuração ausente + cimento Rely X™ U100 (3M ESPE); G2: perfuração ausente + Panavia F2.0 (Kuraray); G3: perfuração presente + Rely X™ U100 (3M ESPE); G4: perfuração presente + Panavia F2.0 (Kuraray). A perfuração foi realizada na superfície radicular com ponta diamantada e selada com agregado de trióxido mineral branco (MTA). Os espécimes foram seccionados para a realização do teste de extrusão por cisalhamento (Push-out) com velocidade de 1mm/min. e célula de carga de 50kgf. Os dados obtidos foram submetidos à Análise de Variância e ao Teste de Tukey (5%). Pôde-se verificar que o cimento resinoso Rely X U100 promoveu os maiores valores de resistência adesiva, independentemente da presença ou não de perfuração radicular; e, ainda, que a presença de perfuração promoveu redução nos valores de resistência adesiva dos cimentos resinosos. Concluiu-se que a presença de perfuração radicular teve efeito direto sobre a resistência adesiva dos pinos de fibra de vidro e dos cimentos resinosos, promovendo redução nos valores de resistência adesiva à dentina intra-radicular


The objective of this paper is to present evaluation of the effect of root perforations on the adhesive resistance (or bond strength) of fiberglass pins – bonded by two resin cements – over the intra-root dentin.. Forty human and sound one--root teeth were subject to endodontic treatment and prepared for having fiberglass pins cemented to them (Exacto Mini, Angelus). The teeth were divided into four experimental groups (n=10), according to the root condition (with or without perforations) and to the resin cement: G1, no perforation, cement Rely X™ U100 (3M ESPE); G2: no perforation+ Panavia F2.0 (Kuraray); G3,: existing perforation + Rely X™ U100 (3M ESPE); G4: existing perforation+ Panavia F2.0 (Kuraray). Perforation was performed on the root surface with diamond tip and sealed with white mineral trioxide aggregate (MTA). The samples were sectioned and a push out test was performed (1mm/minute speed, 50 kgf). The obtained data was submitted to statistical analysis and Tukey test (5%).It was found that the resin cement Rely X U100 caused the highest levels of adhesive resistance regardless of the root perforation and also that perforation produced a reduction of the adhesive resistance of resin cement. The conclusion was that root perforation had a direct effect over the adhesive resistance of fiberglass pins and of resin cement and also produced a reduction in the values of adhesive resistance to the intra-root dentin


Assuntos
Humanos , Cimentação , Cimentos Dentários , Adesivos Dentinários
19.
Camaragibe; s.n; dez. 2010. 106 p. ilus.
Tese em Português | LILACS, BBO - Odontologia | ID: lil-605438

RESUMO

Wste trabalho teve por objetivos avaliar a radiopacidade de cimentos resinosos e pinos de fibra de vidro no filme e sistemas digitais, e a influência destes materiais quando inseridos no canal radicular...


The aim of this study was to evaluate the radiopacity of the resinous cements and glass fiber dowels on film and digital systems and evaluate the influence of these materials when inserted into the root canal...


Assuntos
Pinos Dentários , Intensificação de Imagem Radiográfica , Radiografia Dentária , Cimentos de Resina
20.
Bauru; s.n; 2009. 155 p. ilus, tab, graf.
Tese em Português | BBO - Odontologia | ID: biblio-864904

RESUMO

Este trabalho teve como objetivo avaliar a microdureza de dois cimentos resinosos de polimerização dual (RelyX U100®, 3M-ESPE e Panavia F 2.0®, Kuraray), empregados na cimentação de pinos de fibra de vidro (Fibrekor-Jeneric® Pentron) variando o modo de polimerização em químico, fotoativação imediata ou tardia após 5min através de luz halógena, avaliando também o efeito do armazenamento em água deionizada por três meses. Este trabalho testou as seguintes hipóteses nulas: não há diferença nos valores de microdureza entre os cimentos, modo de polimerização, efeito do armazenamento e entre os terços radiculares. Sessenta raízes de incisivos bovinos, com 16mm de comprimento cérvico-apical, tiveram seus condutos obturados e, posteriormente, preparados para cimentação do pino intracanal. Os espécimes foram divididos em 6 grupos (n = 10), cada um subdividido em 2 subgrupos com 5 espécimes para cada cimento. Os pinos foram cimentados de acordo com o protocolo descrito por cada fabricante. No grupo A1, os espécimes foram mantidos em ambiente à prova de luz para que ocorresse apenas a polimerização química. No grupo B1, os espécimes foram cimentados e submetidos à fotoativação imediata, e, no grupo C1, realizou-se a fotoativação após 5 minutos. As raízes foram seccionadas longitudinalmente, para que a linha de cimento pudesse ser exposta e os testes de microdureza realizados. Após 7 dias, as médias de microdureza (± desvio padrão) foram obtidas, para os terços cervical, médio e apical, respectivamente: A1 (Panavia) - 41,25 ±3,38 / 38,17±1,74 / 35,63±1,73; A1 (U100) - 59,43±4,32 / 52,14±3,00 / 50,27±4,13; B1 (Panavia) - 75,29±4,84 / 60,36±6,76 / 48,97±3,33; B1 (U100) 62,41±6,83 / 53,99±4,74 / 49,04±2,20; C1 (Panavia) - 70,22±93 / 61,00±4,48 / 56,46±7,51; C1 (U100) - 62,40±6,66 / 53,69±2,00 / 51,54±2,18.


Para os grupos armazenados em água, os valores médios de microdureza (± desvio padrão) obtidos nos 3 grupos, químico (grupo A2), fotoativado imediatamente (grupo B2) e fotoativado tardiamente (grupo C2), nos terços cervical, médio e apical, respectivamente, foram: A2 (Panavia) - 37,17±1,38 / 35,01±0,74 / 34,10±2,37; A2 (U100) - 52,39±2,00 / 52,13±3,01 / 51,06±1,48; B2 (Panavia) - 63,01±2,17 / 55,94±2,10 / 48,55±1,62; B2 (U100) - 58,81±2,34 / 55,19±1,42 / 55,71±3,17; C2 (Panavia) - 56,99±1,21 / 51,29±1,81 / 48,29±3,00; C2 (U100) - 59,02±2,04 / 57,05±2,04 / 54,95±1,05. Os resultados foram submetidos ao teste ANOVA a 4 critérios (cimento, modo de polimerização, armazenamento e terços), que detectou diferenças estatísticas entre os grupos, e o teste de Tukey foi aplicado para comparações individuais. Os resultados mostraram que: a fotoativação com luz halógena promoveu um aumento significativo nos valores de microdureza para o cimento Panavia; o armaz namento em água por três meses reduziu os valores de microdureza para a maioria dos grupos, sendo que o cimento o U100 apresentou menor variação de dureza quando comparado ao Panavia; os terços que receberam maior intensidade de luz halógena tiveram maior aumento de microdureza para ambos os cimentos, especialmente para o cimento Panavia. Conclui-se, portanto, que as hipóteses de nulidade propostas foram rejeitadas.


The objective of this study was to evaluate the microhardness of two dual cure resin cements (RelyX - U100®, 3M-ESPE and Panavia F 2.0®, Kuraray), used for fiberglass posts (Fibrekor ® - Jeneric Pentron) cementation. Chemical cure and a halogen immediate and late light cure source were compared, and the effect of storage in deionized water for three months was also evaluated. This study tested the following null hypotheses: there is no difference between the microhardness values for each dual cure resin cement, cure source type, storage time, or root thirds. Sixty bovine incisor roots 16mm long had their roots restored and then prepared for post cementation. The specimens were divided into 6 groups (n = 10), and each group was subdivided into 2 subgroups with 5 specimens for each cement. The posts were cemented according to manufacturers instructions. In group A1, the specimens were kept in a light-proof environment to ensure only a chemical cure. In group B1, the specimens were restored and subjected to immediate light curing, and in group C1, light curing was performed after 5 minutes. The roots were longitudinally sectioned to expose the cement line and perform microhardness tests. After 7 days, the average microhardness (± standard deviation) values were obtained for the cervical, medium and apical thirds, respectively: A1 (Panavia ) - 41,25±3,38 / 38,17±1,74 / 35,63±1,73; A1 (U100) - 59,43±4,32 / 52,14±3,00 / 50,27±4,13; B1 (Panavia) - 75,29±4,84 / 60,36±6,76 / 48,97±3,33; B1 (U100) - 62,41±6,83 / 53,99±4,74 / 49,04±2,20; C1 (Panavia) - 70,22±1,93 / 61,00±4,48 / 56,46±7,51; C1 (U100) - 62,40±6,66 / 53,69±2,00 / 51,54±2,18...


Assuntos
Animais , Bovinos , Cimentos de Resina/efeitos da radiação , Cimentos de Resina/química , Cimentos Dentários , Pinos Dentários , Luz , Materiais Dentários , Testes de Dureza , Teste de Materiais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...